ITEM | DESCRIPTION OF THE PRODUCT |
1 | SPIRAL DUCT 80MM DIA – 1500 MM DIA. METAL GAUGE UP TO 1.2MM |
2 | SPIRAL DUCT FITTINGS LIKE ELBOW, TEE AND Y BRANCH, REDUCER ETC.. ALL SIZES AND ALL METAL GAUGE |
3 | RECTANGULAR DUCT ACCORDING TO SMACNA AND DW149 – ALL SIZES AND ALL METAL GAUGES UP TO 1.2MM |
4 | RECTANGULAR DUCT FITTINGS, ALL SHAPES AND ALL GAUGES |
5 | CIRCULAR AND RECTANGULAR VOLUME CONTROL DAMPERS |
6 | CIRCULAR AND RECTANGULAR FIRE DAMPER – CURTAIN TYPE WITH FUSIBLE LINK UL LISTED |
7 | CIRCULAR AND RECTANGULAR SOUND ATTENUATOR |
8 | PRIMARY FILTERS |
9 | ACCESS DOOR |
10 | CABLE TRUNKING – ALL SIZES WITH COVER |
11 | CUSTOMISED STEEL SUPPORT BRACKETS |
12 | ALUMINIUM AND GALVANISED PIPE CLADDING FOR CHILLED WATER OR CHIMNEY |
ITEM | BASELINE SUPPLY ITEMS |
1 | DUCT FLANGES, CORNERS, GASKETS, G CLAMPS, BOLTS, NUT AND WASHER |
2 | FLEXIBLE DUCT INSULATED AND NON INSULATED OF VARIOUS SIZES – 100MM TO 400MM |
3 | VENTILATION FANS |
4 | CONVASS FLEXIBLE CONNECTION TO FANS, FCU, AHU, ETC |
5 | AIR TERMINALS, GRILLS, DIFFUSERS AND LOUVERS |
6 | COPPER PIPES AND RUBBER INSULATION |
7 | BLACK STEEL PIPES AND ACCESSORIES |
BASELINE FIELD WORK | |
1 | INSTALLATION OF DUCT WORK AND ITS INTERNAL OR EXTERNAL INSULATION |
2 | INSTALLATION OF COPPER REFRIGERANT PIPES C/W RUBBER INSULATION |
3 | INSTALLATION OF CHILLED WATER SYSTEM C/W ALL ASSOCIATED VALVES AND INSULATION |
4 | INSTALLATION OF FANS, HVAC EQUIPMENT |
5 | DUCT AND CHILLED WATER CLADDING |
6 | INSULATION OF VOLUME CONTROL AND FIRE DAMPERS |
7 | START UP – TESTING AND WATER BALANCING – COMMISSIONING OF HVAC SYSTEM |
BASELINE is committed to provide it’s CUSTOMERS with:
• Full Technical Quotations Including Detailed Component list (Description , Catalogs and Brand Name), Bus Bar (Size and Temperature Range), Enclosure (Type, IP, Brand name, Mode of installation).
• Full Technical Submittals Including Detailed Quotations , Shop Drawings (Layout, Power Diagrams, Control Diagrams), Catalogs .
• Full As Built Drawings Including all Technical Specifications,Drawings amended and finalized as per the supplied Switchboards ,which provides Reliable Records for Installation, Cabling, and future Maintenance or Expansion.
• Full Technical Quotations Including Detailed Component list (Description , Catalogs and Brand Name), Bus Bar (Size and Temperature Range), Enclosure (Type, IP, Brand name, Mode of installation).
• Full Technical Submittals Including Detailed Quotations , Shop Drawings (Layout, Power Diagrams, Control Diagrams), Catalogs .
• Full As Built Drawings Including all Technical Specifications,Drawings amended and finalized as per the supplied Switchboards ,which provides Reliable Records for Installation, Cabling, and future Maintenance or Expansion.
BASELINE aims at satisfying customers requirements in the supply of low voltage electrical panel boards by:
• Providing a design tailored to customer needs and intended use in compliance with applicable industry standards.
• Delivering a defect -free product.
• Delivering the product on time.
• Providing a consistent quality.
The inspection and testing of all manufactured products prior to delivery” is the first and last procedure in BASELINE ‘s manufacturing process.
Starting from receiving material from supplier, and ending in the Testing and commissioning area.
Our Quality Control team, independent of the manufacturing process, ensures that the finished product will satisfy the customer.
The quality check is applied at four levels:
1. Visual Inspection.
2. Conformity with design.
3. Labeling and Marking/ Identification.
4. Connection inspection and tightening .
5. Functional test I including insulation test
(High Voltage).
Starting from receiving material from supplier, and ending in the Testing and commissioning area.
Our Quality Control team, independent of the manufacturing process, ensures that the finished product will satisfy the customer.
The quality check is applied at four levels:
1. Visual Inspection.
2. Conformity with design.
3. Labeling and Marking/ Identification.
4. Connection inspection and tightening .
5. Functional test I including insulation test
(High Voltage).